IX Water Results

IX Water Treatment Results

The results below are typical when using the IX Water system to treat hydrocarbon industry water. While not all of the contaminants listed are regulated for a specific industry, vurtually all are found in both oil & gas produced water and coking quench water.

Contaminant

Units

Pre-
Treatment

Post
Treatment

Effective
Removal

Meet or Exceed
Standards?

Benzene mg/L 3.68 0.0050 99.99% YES
Ethylbenzene mg/L 1.33 0.0030 99.74% YES
Toluene mg/L 8.73 0.0102 99.88% YES
Xylenes, total mg/L 4.21 0.0036 99.91% YES
Aluminum ug/L 18,300 35.7 99.80% YES
Arsenic ug/L 87.9 ND 100% YES
Barium mg/L 2.01 0.004 99.99% YES
Beryllium ug/L 14.1 ND 100% YES
Cadmium ug/L 18.1 ND 100% YES
Calcium mg/L 1,030 0.050 99.99% YES
Chromium III ug/L 330 1.7 99.48% YES
Copper ug/L 634 ND 100% YES
Iron ug/L 9,950 25.6 99.97% YES
Iron (Suspended) mg/L 80 ND 100% YES
Lead ug/L 1,250 ND 100% YES
Magnesium mg/L 407 ND 100% YES
Manganese ug/L 17,100 ND 100% YES
Nickel ug/L 290 7.5 97.41% YES
Potassium mg/L 151 ND 100% YES
Thallium ug/L 8.6 ND 100% YES
      Average 99.81%  